The RCCx reactive current control detects reactive current in a single- or three- phase line and closes its output contacts if above the set limit. It can thus dynamically compensate low inductive power factor lines by signaling the need to switch capacitors in and out of the line.
It is very simple to install and adaptable to all power factor compensation applications.
The RCCx ...
Single Reactive Current Controlled Switch
The RCCS1 switches measure the reactive current in a three phase 3x400 VAC system and activate one 8 A solid state switch to connect one three phase compensating capacitor in and out of the three phase line. The current is detected with a current transformer (CT) in one of the line phases and the sampling period is selectable from 4 to 32 seconds.
The ...
Triple Reactive Current Controlled Switch
The RCCS3 switches measure the reactive current in a three phase 3x400 VAC system and activate three 8 A solid state switches to connect three phase compensating capacitors in and out of the three phase line. The current is detected with a current transformer (CT) in one of the line phases and the sampling period is selectable from 4 to 32 seconds.
The ...
SYSTÈME AUTOMATIQUE DE COMPENSATION DE PHASE (APFC)
Vue d'ensemble de produit
APFC est employé pour la compensation centralisée de puissance réactive au moment où l'accouplement commun (PCC) du système électrique de distribution composé de charges variables.
APFC a une banque de condensateur subdivisée en un ou plusieurs nombre d'étapes, qui peuvent être alimentées et et automatiquement ...
STATCOM
Vue d'ensemble de produit
STATCOM est employé pour la compensation centralisée de puissance réactive et la suppression harmonique dans un système d'alimentation.
STATCOM est un dispositif basé par IGBT de l'électronique de puissance. Il emploie IGBT et technologie d'inverseur.
Il activement élimine la déformation harmonique de 100% et réagit immédiatement aux charges ...
Compensateur de filtrage dynamique de NTSC
Application : applicable pour des endroits exigeant la compensation réactive dynamique ou la commande harmonique, particulièrement approprié aux occasions avec le moulin, la soudeuse de tache, la grue, l'ascenseur et le trafic.
Paramètres :
 ; Tension évaluée : AC0.4-1kV
 ; Facteur de puissance : 0.9
 ...
Métal PFC inclus avec les filtres harmoniques
Des batteries de filtres harmoniques incluses par métal devraient être considérées quand la compensation de phase est désirée dans un environnement harmonique. La batterie de filtres se compose d'une clôture contenant des condensateurs de compensation de phase reliés en série aux réacteurs compensés harmoniques de noyau de fer. La fréquence ...
Des filtres de protection sont utilisés sur les réseaux de distribution qui ont un haut THD (déformation harmonique totale), quand la cible finale est de compenser le facteur de puissance à la fréquence fondamentale.
Son but est d'éviter des surcharges dues aux courants harmoniques dans le condensateur, les guidant au réseau.
Des filtres de protection sont faits avec les réacteurs ...
La ligne de GEMTRAP® des condensateurs fixes et avec harmonie supprimés permet l'installation des condensateurs de compensation de phase sur des systèmes avec les composants non linéaires de charge. Le système de GEMTRAP® peut être accordé à n'importe quelle fréquence désirée mais est normalement accordé au 4.7th harmonique.
Matrix TM Harmonic Filters substantially reduce total harmonic current distortion in AC variable speed drive system applications where the variable speed drive uses a six-pulse diode bridge input rectifier. The filter is installed in series with the inverter or drive.
Des banques de filtre de harmonique incluses par métal devraient être considérées quand la compensation de phase est désirée dans un environnement harmonique. La banque de filtre se compose d'un boîtier contenant des condensateurs de compensation de phase reliés dans la série aux réacteurs compensés harmoniques de noyau de fer. La fréquence de résonance des égales de filtre qui de l'harmonique à éliminer ...
Tuned Harmonic Filters (Type FFB and Type FAB) 200-690 volts 50/60Hz
Arteche Tuned Harmonic Filters reduce power system harmonic distortion and improve power factor. Most commonly, these Arteche filters are tuned for the 5th harmonic, but Tuned Harmonic Filters are available to filter any harmonic frequency. Filters may also be designed to remove more than one harmonic frequency (ie: 5th ...
Enclosed Harmonic Filters & Capacitors
Pad Mount & Switchgear style enclosed systems
Custom engineered solutions for both utility and industrial applications, our capacitor systems and harmonic filters
are available in both pad mount or switchgear style enclosures. Switchgear style units are typically located at the
main service entrance of an industrial facility and ...
multimod-F - plug-in design
Reactive current compensation modules
Power from 10 to 100 kvar
Inductor factors 5.5, 7 or 8 % and 12.5 or 14 %
Capacitor rated voltage with 440 V or 525 V
For cabinet widths of 600 or 800 mm
For cabinet depths of 400, 500 or 600 mm
multimod-F - thyristor switched / plug-in design
Reactive current compensation module
Power from 12.5 to 50 kvar
Inductor factors 5.5, 7 or 8 % and 12.5 or 14 %
Capacitor rated voltage 525 V
For cabinet widths 800 mm
Long working life through unlimited switching frequency
No noise generation
Short switching times
PANNEAU DE COMMANDE
Cet équipement convient à l'installation d'intérieur et dans un environnement well-ventilated sans poussière, protégé contre des chocs et des impacts accidentels et lumière du soleil directe.
La ventilation forcée est obtenue au moyen de ventilateurs thermostatique-commandés avec l'échappement supérieur d'air.
L'équipement doit être installé dans un environnement ...
Filtre actif modulaire de puissance
Conception modulaire, facile à se prolonger
Jusqu'au cinquante-et-unième harmonique
Jusqu'à 12 ordres harmoniques sélectifs individuellement
Compensation de phase programmable
Système de commande à temps plein de DSP
Choix facile
Raccordement de shunt, facile pour l'entretien
Évolution flexible/redondance
Le parallèle a fonctionné ...
L'équipement libre automatique, série d'ERAF a été spécifiquement conçu pour la correction industrielle de puissance-facteur ou milieu-grand-mesure des opérations dans les réseaux avec la déformation harmonique.
Fréquence de accord 189Hz (p=7%)
sur demande : 134Hz (p=14%) - 210Hz (p=5.67%)
Metal l'armature équipée des ailerons de refroidissement, RAL 7032, CTF-type support modulaire, régulateur, ...